引用本文
  •    [点击复制]
  •    [点击复制]
【打印本页】 【下载PDF全文】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 2149次   下载 0 本文二维码信息
码上扫一扫!
亚硝酸钠滴定液标定的不确定度评估
李华岑
0
(河南省兽药监察所)
摘要:
应用测量不确定度评定与表达的理论,以标定亚硝酸钠滴定液为例,分析了影响滴定液浓度测量不确定度的因素,包括标定过程中测量重复性、天平、滴定管、基准物纯度等因素,计算得出亚硝酸钠滴定液浓度测定结果的扩展不确定度为0.0001 mol/L。
关键词:  亚硝酸钠滴定液  浓度  测量不确定度
DOI:
投稿时间:2009-04-02修订日期:2009-05-04
基金项目:
Evaluation on the Uncertainty of Measurement of the Concentration of Sodium Nitrite Volumetric Solution
lihuacen
(Henan Provincial Supervisory Institute of Veterinary Drug)
Abstract:
The impact factors in the uncertainty of measurement of volumetric solution concentration were analysed using the theory of assessment and expression of uncertainty monitoring with the example of the determination of the concentration of sodium nitrite volumetric solution. The factors effecting on the uncertainty of measurement in the determination of the concentration were evaluated, including repeatability of measurement results, balance, burette, the purity of standard reagent, etc. The expanded uncertainty was 0.0001 mol/L.
Key words:  sodium nitrite volumetric solution, concentration, uncertainty of measurement

用微信扫一扫

用微信扫一扫